Posted on July 2nd, 2019 by Met-Tech
Failure Analysis of Failed Inconel Condenser Tube Metallurgical Failure Analysis – Forensic Engineering Metallurgical failure analysis provided by MTi can help minimize and eliminate the extreme effects of unexpected down time in the power industry. We specialize in rapid response with prompt report turnaround. When the root cause of the metal product failure is […]
Tags: caustic corrosion, caustic material, Condenser Tube, crevice corrosion, Failed Inconel Condenser Tube, Failure Analysis
Posted on July 9th, 2019 by Met-Tech
Failure Analysis of Fractured Tool Steel Die Plate Summary: A cracked polymer filament die plate was received for analysis to determine the cause of cracking. Results indicate the die plate cracked as a result of a brittle nitrided case and an insufficient cross-sectional area of the narrow ligament between the cap screw hole and […]
Tags: Cracked Nitrided Tool Steel Die Plate, Die plate, Failure Analysis, Failure Analysis of Fractured Tool Steel Die Plate, Nitrided tool steel, polymer filament die plate