Cracked Nitrided Tool Steel Die Plate
Posted on July 9th, 2019 by Met-Tech
Failure Analysis of Fractured Tool Steel Die Plate Summary: A cracked polymer filament die plate was received for analysis to determine the cause of cracking. Results indicate the die plate cracked as a result of a brittle nitrided case and an insufficient cross-sectional area of the narrow ligament between the cap screw hole and […]